Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-37579604

RESUMO

A hybrid immunoaffinity LC-MS/MS assay was developed and validated for the quantitation of total antibody (TAb) from an antibody drug conjugate (ADC) PYX-201 in human plasma. PYX-201 was proteolyzed using trypsin, and a characteristic peptide fragment PYX-201 P1 with ten amino acids IPPTFGQGTK from the complementarity-determining regions (CDRs) was used as a surrogate for the quantitation of the TAb from PYX-201. Stable isotope labelled (SIL) peptide I(13C6, 15N)PPTFG(13C9, 15N)QGTK was used as the internal standard (IS). We performed chromatographic analysis using a Waters Acquity BEH Phenyl column (2.1 mm × 50 mm, 1.7 µm). Quantification of PYX-201 TAb was carried out on a Sciex triple quadrupole mass spectrometer API 6500 using multiple reaction monitoring (MRM) mode with positive electrospray ionization. To validate PYX-201 TAb, a concentration range of 0.0500 µg/mL to 20.0 µg/mL was used, yielding a correlation coefficient (r) of ≥ 0.9947. For intra-assay measurements, the percent relative error (%RE) ranged from -23.2% to 1.0%, with a coefficient of variation (%CV) of ≤ 14.2%. In terms of inter-assay measurements, the %RE was between -10.5% and -5.7%, with a %CV of ≤ 12.7%. The average recovery of the analyte was determined to be 81.4%, while the average recovery of the internal standard (IS) was 97.2%. Furthermore, PYX-201 TAb demonstrated stability in human plasma and human whole blood under various tested conditions. This assay has been successfully applied to human sample analysis to support a clinical study.


Assuntos
Fragmentos de Peptídeos , Espectrometria de Massas em Tandem , Humanos , Cromatografia Líquida/métodos , Espectrometria de Massas em Tandem/métodos , Reprodutibilidade dos Testes
2.
Anal Chem ; 92(16): 11135-11144, 2020 08 18.
Artigo em Inglês | MEDLINE | ID: mdl-32459957

RESUMO

Complex biotherapeutic modalities, such as antibody-drug conjugates (ADC), present significant challenges for the comprehensive bioanalytical characterization of their pharmacokinetics (PK) and catabolism in both preclinical and clinical settings. Thus, the bioanalytical strategy for ADCs must be designed to address the specific structural elements of the protein scaffold, linker, and warhead. A typical bioanalytical strategy for ADCs involves quantification of the Total ADC, Total IgG, and Free Warhead concentrations. Herein, we present bioanalytical characterization of the PK and catabolism of a novel ADC. MEDI3726 targets prostate-specific membrane antigen (PMSA) and is comprised of a humanized IgG1 antibody site-specifically conjugated to tesirine (SG3249). The MEDI3726 protein scaffold lacks interchain disulfide bonds and has an average drug to antibody ratio (DAR) of 2. Based on the structural characteristics of MEDI3726, an array of 4 bioanalytical assays detecting 6 different surrogate analyte classes representing at least 14 unique species was developed, validated, and employed in support of a first-in-human clinical trial (NCT02991911). MEDI3726 requires the combination of heavy-light chain structure and conjugated warhead to selectively deliver the warhead to the target cells. Therefore, both heavy-light chain dissociation and the deconjugation of the warhead will affect the activity of MEDI3726. The concentration-time profiles of subjects dosed with MEDI3726 revealed catabolism of the protein scaffold manifested by the more rapid clearance of the Active ADC, while exhibiting minimal deconjugation of the pyrrolobenzodiazepine (PBD) warhead (SG3199).


Assuntos
Antineoplásicos/farmacocinética , Benzodiazepinas/farmacocinética , Imunoconjugados/farmacocinética , Imunoglobulina G/metabolismo , Pirróis/farmacocinética , Antineoplásicos/sangue , Antineoplásicos/metabolismo , Benzodiazepinas/sangue , Benzodiazepinas/metabolismo , Humanos , Imunoconjugados/sangue , Imunoconjugados/metabolismo , Imunoglobulina G/sangue , Antígeno Prostático Específico/imunologia , Pirróis/sangue , Pirróis/metabolismo
3.
Antibodies (Basel) ; 8(1)2019 Jan 11.
Artigo em Inglês | MEDLINE | ID: mdl-31544817

RESUMO

Bioanalysis of complex biotherapeutics, such as antibody-drug conjugates (ADCs), is challenging and requires multiple assays to describe their pharmacokinetic (PK) profiles. To enable exposure-safety and exposure-efficacy analyses, as well as to understand the metabolism of ADC therapeutics, three bioanalytical methods are typically employed: Total Antibody, Antibody Conjugated Toxin or Total ADC and Unconjugated Toxin. MEDI4276 is an ADC comprised of biparatopic humanized antibody attached via a protease-cleavable peptide-based maleimidocaproyl linker to a tubulysin toxin (AZ13599185) with an approximate average drug-antibody ratio of 4. The conjugated payload of MEDI4276 can undergo ester hydrolysis to produce the conjugated payload AZ13687308, leading to the formation of MEDI1498 (de-acetylated MEDI4276). In this report, we describe the development, validation and application of three novel multiplex bioanalytical methods. The first ligand-binding liquid chromatography coupled with tandem mass spectrometry (LBA-LC-MS/MS) method was developed and validated for simultaneous measurement of total antibody and total ADC (antibody-conjugated AZ13599185) from MEDI4276. The second LBA-LC-MS/MS assay quantified total ADC (antibody-conjugated AZ13687308) from MEDI1498. The third multiplex LC-MS/MS assay was used for simultaneous quantification of unconjugated AZ13599185 and AZ13687308. Additional stability experiments confirmed that quantification of the released warhead in the presence of high concentrations of MEDI4276 was acceptable. Subsequently, the assays were employed in support of a first-in-human clinical trial (NCT02576548).

4.
Bioanalysis ; 8(8): 765-94, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-27005848

RESUMO

BACKGROUND: Knowledge of antipsychotic drug levels at point of care (POC) may significantly aid therapeutic decision-making. To support the development of future POC devices and to validate the use of fingerstick capillary blood sampling, two robust hydrophilic interaction LC-ESI/MS/MS methods were developed and validated. Two PK studies were completed evaluating the correlation between fingerstick blood and plasma concentrations with corresponding venous blood and plasma concentrations for several commonly prescribed atypical antipsychotics and selected metabolites. Sensitive and reliable LC-MS/MS bioanalytical assays were developed to support these studies. RESULTS: Three methods, requiring only 25-µl matrix volumes, were developed using supported liquid extraction with hydrophilic interaction LC-MS/MS detection and validated according to regulatory guidance. CONCLUSION: Robust and efficient LC-MS/MS assays were established and were effective in providing antipsychotic drug matrix comparator results in the intended clinical studies.


Assuntos
Antipsicóticos/sangue , Análise Química do Sangue/métodos , Cromatografia Líquida de Alta Pressão , Espectrometria de Massas por Ionização por Electrospray , Antipsicóticos/farmacocinética , Antipsicóticos/normas , Análise Química do Sangue/normas , Calibragem , Cromatografia Líquida de Alta Pressão/normas , Meia-Vida , Humanos , Sistemas Automatizados de Assistência Junto ao Leito , Reprodutibilidade dos Testes , Espectrometria de Massas por Ionização por Electrospray/normas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...